| 5.1 | deck connections minimise risk of cross contamination |  |
| deck connections clearly marked 'PETROL' |  |
| deck connections clearly marked 'PETROIL' |  |
| deck connections clearly marked 'PARAFFIN' |  |
| deck connections clearly marked 'DIESEL' |  |
| deck connections clearly marked 'LPG BUTANE/PROPANE' as appropriate |  |
| deck connections clearly marked 'WATER' |  |
| deck connections clearly marked 'PUMP OUT' |  |
| deck connections clearly marked 'RINSE OUT' |  |
| deck connection markings on deck fitting or immediately beside deck connections |  |
|
| 5.2 | permanent fuel systems fixed/constructed to Standards 2.1-2.19 |  |
| permanent fuel systems suitably protected against external impact |  |
| fuel systems - permanent pipework suitably |  |
| protected against external impact |  |
| fuel systems - permanent fuel cocks suitably |  |
| protected against external impact |  |
|
| 5.3 | portable/close coupled fuel tank in sound condition |  |
| fuel tank - portable/close coupled - fuel supply not capable of being readily shut off |  |
| fuel tank - portable/close coupled - unauthorised modifications made |  |
| fuel tank - portable/close coupled - not clearly marked with type of fuel used |  |
| portable fuel tank - not in use - Not stowed in accordance with Standards 7.2 and 7.3 of these Standards |  |
|
| 5.4 | spare petrol carried in approved containers conforming to petroleum spirit regulations |  |
| spare petrol containers stowed in accordance with Standards 7.2 and 7.3 of these Standards |  |
|
| 5.5 | LPG engines comply with LPGA code of practice No. 18 LPG Engines not dual fuel system |  |
|
| 5.6 | outboard engine securely fitted |  |
|
| 5.7 | exhaust noise effectively suppressed |  |
|
| 5.8 | portable LPG/petrol engines generators with integral tanks stowed in accordance with standards 7.2 and 7.3 of these standards |  |
| portable diesel generators with integral tanks stowed in accordance with Standards 7.2 and 7.3 of these Standards |  |
| portable diesel generators stored securely |  |
| portable diesel engines stored securely |  |
|
| Check List items in bold are Mandatory | |
| Check List items in italic are Advisory | |
| *EXEMPTION AVAILABLE | |